site stats

Fitmore hip stem

WebJan 7, 2024 · On the other hand, studying the metaphyseal-anchored Fitmore hip system (Fitmore®, Zimmer Inc., Warsaw, IN, USA), Gustke described subsidence of more than 2 mm on plain radiographs in 34% of 100 examined THA after a mean follow-up of 1.3 years. However, none of these implants had to be revised during this short follow-up . In our … WebMar 21, 2011 · Description. The Zimmer Fitmore stem system is a curved, short (44 to 60 mm in length), uncemented femoral stem with a trapezoidal cross section and triple taper geometry, available since 2008. The device is manufactured from Zimmer’s Protasul™ titanium alloy, has a proximal Ti-plasma coating and is distally rough blasted.

The morphology of the proximal femur in cementless short-stem total hip ...

WebThe Fitmore Hip Stem is a curved uncemented stem The Fitmore Hip Stem offers a wide range of offset with a trapezoidal cross section, which is coated options to address a wide variety of anatomic offsets proximally with Ti-VPS … WebDec 20, 2024 · Fitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) and 14 different sizes (size 1–14) for each offset option . A cementless titanium press-fit cup with or without screws ... the balanced snack box - the big snacker https://burlonsbar.com

Cortical hypertrophy with a short, curved uncemented hip stem …

WebThe Zimmer Biomet primary hip portfolio encompasses femoral and acetabular systems, instruments and support services to address the distinct needs of individual patients, while simplifying the surgical workflow. ... Fitmore® Hip Stem. CPT® 12/14 Femoral System. Avenir® Hip System. Acetabular Reconstruction. G7 ® Acetabular System. WebApr 1, 2014 · DOI: 10.1016/j.jocd.2013.11.001 Corpus ID: 2830715; Osseointegration of Fitmore stem in total hip arthroplasty. @article{Gasbarra2014OsseointegrationOF, title={Osseointegration of Fitmore stem in total hip arthroplasty.}, author={Elena Gasbarra and Monica Celi and Fabio Luigi Perrone and Riccardo Iundusi and Luigia Anna Di … WebJan 1, 2016 · Fitmore Hip Stem saving the bone mass in the area of greater trochanter and diaphysis of . the femur. It has different curves in order to restore the hip joint anatomy and achieve a . the balanced voice podcast

Cortical hypertrophy with a short, curved uncemented hip stem …

Category:Bone remodelling of the proximal femur after hip revision TCRM

Tags:Fitmore hip stem

Fitmore hip stem

First experiences with the Fitmore® hip stem: Early results …

WebJun 24, 2024 · The Fitmore hip stem is an uncemented short curved hip stem available in four different offset options with a CCD-Angle ranging from 140 to 127° [A (140°), B (137°), B extended (129°) and C (127°)]. Every offset option is available in 14 different sizes. Allofit cup is a bi-hemispherical press fit cup with sizes ranging from 42 to 68 mm. WebCurrently, an increasing number of younger patients undergo total hip arthroplasty surgery. This has led to a minimal invasive approach and the use of short, bone preserving, …

Fitmore hip stem

Did you know?

WebMay 27, 2024 · Background An increased occurrence of cortical hypertrophy (CH) was observed 1–2 years after implanting short curved Fitmore hip stems. There are no … WebApr 18, 2011 · Fitmore® Hip Stem Manufacturing Process . HCP Content Posted April 18, 2011 in Manufacturing Videos

WebExplore más de 120,000 registros de retiros, alertas y notificaciones de seguridad de dispositivos médicos y sus conexiones con los fabricantes. WebThe Fitmore Hip Stem's short length and curved design helps preserve the patient's natural bone in the greater trochanter, where it matters most. Zimmer Biomet has been at the forefront of less invasive approaches to total hip arthroplasty. As the leader in Minimally Invasive Solutions™ procedures, Zimmer Biomet is proud to introduce the ...

WebThe Avenir Complete Hip System is compatible with ONE Planner Hip, a web-based preoperative planner for primary total hip arthroplasty. Using the auto-plan mode, surgeons can create a preoperative plan within five minutes. ONE Planner Hip features an optional spinopelvic mobility assessment tool if both a sitting and standing lateral x-ray are ... WebMay 27, 2024 · Background: An increased occurrence of cortical hypertrophy (CH) was observed 1-2 years after implanting short curved Fitmore hip stems. There are no published data about either the clinical relevance or the progression of CH over the long term. Methods: Ninety-six primary total hip arthroplasties were performed between 2008 and …

WebJan 6, 2016 · The Fitmore Hip Stem (Zimmer, Winterthur, Switzerland) is a curved, uncemented triple-tapered stem made from titanium alloy. Proximally, it has a titanium vacuum plasma spray coating, while the …

WebProvide accessible, affordable, high quality, specialized orthopaedic services, physical medicine, rehabilitation, and physical and occupational therapy services that meet the needs of our community. Motivate and educate patients and their families to achieve an optimal level of functioning. Be a leader in supporting and sponsoring community ... the green room salonWebThe Zimmer femoral stems and necks are metal alloy implants used for hip replacements that allow the surgeon to fit the implant specifically to the patient. During hip replacement surgery, the damaged portions of the … the balanced word radio broadcastWebThe Fitmore Hip Stem offers a wide range of offset options to address a variety of anatomic offsets among individuals. Biomechanical characteristics such as the femoral offset and the leg length can be restored while … the green room sag harborWebSep 23, 2024 · The Fitmore ® hip stem shows a high primary stability comparable to straight stem systems . The survival rate of the Fitmore ® hip stem after 8.6 years is reported with 99.6% (95% CI 97.1–99.9%) for the endpoint of “stem revision due to aseptic loosening”. However, the long-term impact of a low Canal Fill Index because of a high … the balanced wordWebOct 10, 2024 · Class 2 Device Recall FITMORE HIP STEM. All product manufactured prior to January 2014. Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). The firm distributed Urgent Medical Device Correction letters to customers on October 10, 2024. The letter informed customers that the previous version … the greenroom salon boca ratonWebThe aims of this study were to identify whether the bone mineral density (BMD) of the proximal femur increases following hip revision with a metaphyseal-fixation femoral stem and to identify the factors associated with BMD recovery. Methods: This was a retrospective study involving 36 patients who underwent hip arthroplasty with a metaphyseal ... the balanced scorecard is very helpful as aWeb5 Fitmore Hip System - Ordering Information Fitmore General Instrument Set Product Description Size Quantity Product Number Fitmore Curved Hand Rasp – 1 00-7942-020 … the balance ffxiv dark knight